This is set by the roof use you selected in the previous screen and cannot be modified.
Roofing australian timber span tables.
Span charts and 2012 irc building codes for girders and headers.
Children s nightwear and limited daywear having reduced fire hazard.
Table assumes a maximum flooring mass of 40kg.
Joists crippled over supports shall be considered as single span joists.
Lintel span sheet roofing tiled roofing roof load width rlw mm 1500 2100 4500 7500 1500 2100 4500 7500 maximum span of lintel mm 90 x 35 600 2000 1800 1400 1200.
2 for design parameters refer to figure 7 26.
Includes span tables for all load bearing locations and the number of jack studs.
A maximum roof pitch of 25 degrees is assumed.
Stress grades and timber sizes combine to determine the spanning ability of load carrying members.
Span tables allow users to choose an appropriate size and stress grade to achieve spanning needs.
Residential timber framed construction part 2.
Loads are calculated in accordance with table 3 1 of as nzs 1170 1 2002.
Wind classification 1 n2.
The imposed uniformly distributed live load in the main span.
Technical diagram span tables f7 rafters on page 35 30mm m aximum allow able sp ans mm sheet roof spacing mm rafter size 600 760 900 1000 1200 66 x 30 1250 1150 1050 1000 950 90 x 30 1650 1550 1550 1400.
Construction details should be in accordance with as1684 2.
Roof load width rlw and floor load width flw can be determined from as1684 or from the images below.
Posts these span tables are designed for a minimum post size of 50 x 50 x 2 5mm up to a maximum height of 3 0m.
1 refer to general notes for information that is relevant for all span tables.
For simple construction such as domestic construction this can be determined from span table supplements in as1684 2 and as1684 3.
Spacing should be interpreted as the centre to centre distance between adjacent parallel members.
Spanman increase member sizes in accordance with australian codes if the member supports brittle loads.
Use recommended minimum roof pitches as specified by roof sheet supplier.
These charts are for 30 pound per square foot snow load on the roof.
Electrical installations known as the australian new zealand wiring rules bridge design part 1.
All other data is available on page 121 of the 2012 international residential code.
Flat roof span tables allow for a maximum roof pitch of 5ยบ.
If the manual.
Member tables for seasoned timber stress grade f17.
3 where rafters are equal to or exceed four times their breath blocking should be used to reduce distortion.